Cars · Electronics

OBD0 & OBD1 VTEC RPM Formula

RPM conversion formula for OBD0 and OBD1 VTEC activation values.

Beginner

Adapted from pgmfi.org wiki

In OBD0 and OBD1 Honda VTEC ECUs, the VTEC engagement and disengagement thresholds are determined using the following formula:

RPM = (Decimal_Value - 128) * 62.52

Where:

  • Decimal_Value is the base-10 value of the byte located at the VTEC RPM activation/deactivation addresses in the ROM.

Credits and source

Authors Anonymous PGMFI contributor

Source Adapted from OBD0VTEC on pgmfi.org wiki. Licensed under CC BY-NC-SA 1.0.